Leasing a Grade A office isn’t just about an impressive lobby—it’s about safeguarding mission-critical operations, meeting regulatory demands and nurturing talent. Drawing on projects across Singapore, Malaysia and China, AND laboutlines the non-negotiables every bank, fintech or insurer should check before signing a lease.


1 Mechanical & Environmental Control

  • 24/7 VRV / VRF air-conditioning with N+1 redundancy keeps trading floors and server rooms cool without oversizing chillers.

  • Dedicated CRAH/CRAC units or in-row coolers for server racks maintain ≤24 °C / 45 % RH, satisfying MAS and BNM tech-risk guidelines.

 

2 Raised Floor & Underfloor Air Distribution (UFAD)

A 600 × 600 mm steel-cement raised floor allows concealed cabling, fast churn and UFAD supply air at 16–18 °C—cutting fan energy up to 30 %. Floor loading ≥12 kN/m² supports dense racks.

 

3 Robust Electrical & Power Redundancy

Dual 11 kV substations, UPS plus diesel gensets (48 h autonomy) and separate clean/dirty earthing deliver Tier 2 resilience that regulators expect.

 

4 Security, Fire & Compliance

  • Bank-grade access control with biometrics and man-trap vestibules.

  • FM-200 or Novec 1230 gas suppression paired with VESDA for early smoke detection.

  • CCTV retention ≥90 days to satisfy local banking rules.

 

5 Digital Connectivity & Low-Latency Routing

Carrier-neutral meet-me rooms with ≥3 diverse fibre routes achieve sub-2 ms hops to Bursa, SGX or HKEX; in-building 5G DAS provides a mobile trading fallback.

 

6 Sustainability & Wellness

Target LEED Gold or BCA Green Mark Platinum for energy intensity cuts >25 %, and consider WELL Core v2 to boost IAQ, circadian lighting and ESG scores.

 

7 Prime Location & Executive Amenities

CBD clusters offer regulator proximity and talent retention. Look for destination-controlled lifts, sky-lounge meeting suites and 3 m clear trading-floor heights.

 

8 Future-Ready Floorplates & Fit-Out Flexibility

Column-free spans ≥18 m and raised floor/ceiling voids ≥450 mm simplify agile layouts and save up to 50 % in churn costs across a 10-year lease.

Quick Checklist for Finance Tenants

Must-Have Why It Matters
24/7 VRV/VRF + back-up Continuous cooling
Raised floor ≥ 600 mm Cabling & UFAD
N+1 generators & UPS Regulatory uptime
Gas fire suppression Protects hardware
≥3 carrier fibre routes Low-latency trading
LEED / WELL certified ESG & talent

 

Ready to Evaluate Your Next HQ?

As a regional workplace design specialistAND lab translates these technical must-haves into turnkey interiors that protect critical operations while elevating brand value across Asia-Pacific. Talk to our team to benchmark prospective buildings or plan a fit-out that outperforms.